Product Intro:
Intelligent universal circuit breaker is one of the circuit breakers developed by this adopted technology, which is suitable for general power distribution system, new energy distribution system, multi-energy distribution network, inverter and distributed power supply rotating motor class power grid operation and protection, etc. It has isolation function and small size, high breaking capacity, and other multi-functional features.
Summarize
Intelligent universal circuit breaker is one of the circuit breakers developed by this adopted technology, which is suitable for general power distribution system, new energy distribution system, multi-energy distribution network, inverter and distributed power supply rotating motor class power grid operation and protection, etc. It has isolation function and small size, high breaking capacity, and other multi-functional features.
Rated operating voltage AC400V/690V
Rated frequency 50Hz
Rated current 200A-1600A
● There are three and four
● Drawer type and fixed type can be inverted into the line connection
● Use category B
● Implementation standard GB14048.2-2008
● Conformity with standards
IEC60947- 1 and GB14048.1 -2012 General provisions for low-voltage switchgear and controlgear.
IEC60947-2 and GB14048.1-2008 Circuit breakers for low-voltage switchgear and control equipment
IEC60947-4- 1 and GB 14048.4 Low-voltage switchgear and controlgear electromechanical contactors and motor starters including motor protectors
Model Meaning
Normal Conditions of Use and Installation
● The surrounding air temperature should be -5℃~+40℃ (beyond the range can be used with reduced capacity), and the average value of 24h should not exceed +35℃;
● The altitude of the installation site does not exceed 2000 meters above sea level, and it can be used with reduced capacity if it exceeds 2000 meters;
● The relative humidity of the air at the installation site does not exceed 50% at a temperature of +40℃, and can be higher at lower temperatures, e.g. 90% at 20℃, and measures should be taken for occasional condensation due to temperature changes;
● Pollution class 3;
● The installation category of the main circuit of the circuit breaker is IV, and the installation category of the remaining auxiliary and control circuits is III;
● The circuit breaker shall be installed in a place where there is no danger of explosion, no conductive dust, no rain or snow, and no place where there is sufficient corrosion of metal and damage to insulation.
Main Technical Indicators
Intelligent Universal Circuit Breaker (Drawer Type) Mounting Dimensions
Intelligent Universal Circuit Breaker (Drawer Type) Mounting Dimensions
△ Steel cable interlocking of two flat or stacked circuit breakers
Note: The length of steel cable for steel cable interlocking is 2.5m, 1.5m steel cable can also be provided, but users need to specify when ordering. △Interlocking of two stacked circuit breakers with interlocking rods
Fixed and drawer type
Note: The distance between the upper and lower mounting plates is 0.6m~0.7m.
"Break" locking device
The "open gate" locking device can lock the break button of the circuit breaker in the pressed position, at this time, the circuit breaker will not be able to close.
Factory supplied locks and keys when fitted as an option to the user; three circuit breakers with three identical locks and two keys.
Drawer and Fixed
Note: The distance between the upper and lower mounting plates is 0.6m~0.7m.
"Break" locking device
The "open gate" locking device can lock the break button of the circuit breaker in the pressed position, at this time, the circuit breaker will not be able to close
Factory supplied locks and keys when fitted as an option to the user; three circuit breakers with three identical locks and two keys.
Drawer and Fixed